TRI-CORD PLUG GFCI 120VAC 15A 12AWG

TRI-CORD PLUG GFCI 120VAC 15A 12AWG

tri-cord plug gfci 120vac 15a 12awg

Stellar Part #COLEM 14880 023-6

MFG Part #14880023-6

MFG Name:Southwire Company

Product Description:

Southwire Surge Guard 14880023-6 1-ph Type SJTW-A Heavy Duty Right Angle GFCI Plug Tri-Cord, 120 VAC, 15 A, 12 AWG Conductor, 3 Outlets
Login For Price
  • Heavy duty molded T-head with three receptacles
  • 3 kV ringwave test and 4 kV/2 kA surge immunity test voltage surge withstand
  • Operates within normal limits with 0.5 volts injected on power line 150 kHz to 230 MHz radio frequency noise susceptibility
  • 3000 operations minimum endurance
  • Six times rated overload current
  • 5% maximum trip level variation effect of 10 A turn DC shock on ground fault trip
  • 1500 VRMS - 1 min insulation voltage
  • Mechanical indicator
  • Manual reset
  • Heavy impact-resistant polymer material
  • The gfci is an integral part of male plug
  • Provides protection for the extra heavy duty cord and three attached tools
  • 12 ga cord is ideal for outdoor rugged construction type environments
  • To prevent unmonitored equipment startup, manual reset is required after GFCI trip and power outage
  • Provides compliance with national electric code (NEC 2008) article 590.6 for temporary installations
  • 4 to 6 ma trip level
  • 4 Ohm typical grounded neutral
  • Less than 25 ms trip response time for ground fault and grounded neutral trip