Southwire® Surge Guard® 14880012-6 Type SJTW-A Heavy Duty Right Angle GFCI Cord Set, 120 VAC, 15 A, 12 AWG Conductor
set cord gfci 120vac 15a 12awg 50/60hz 3
Stellar Part #COLEM 14880 012-6
MFG Part #14880012-6
MFG Name:Southwire Company
Product Description:
Southwire® Surge Guard® GFCI Cord Set, Type SJTW-A Heavy Duty Right Angle, 120 VAC, 15 A, 50/60 Hz Frequency, 12 AWG Conductor, 3 Conductors, -35 to 66 deg C Operating, NEMA 5-15R Receptacle, NEMA 5-15P Plug, Polymer, Yellow, 9 in L x 2.04 in W Dimensions
Login For Price
- Item Features
- Technical Specifications
- Resources
- GFCI right angle cord sets are ideal for use by contractors and industrial maintenance personnel working with extension cords or portable tools
- Six times rated current overload current
- 5% maximum trip level variation effect of 10 A turn DC shock on ground fault trip
- 1500 Vrms to 1 min insulation voltage
- Mechanical indicator
- Manual reset
- Heavy impact resistant polymer material
- Provides compliance with national electric code (NEC 2008) article 590.6 for temporary installations
- Rainproof rated, UL listed for outdoor use
- To prevent unmonitored equipment startup, manual reset is required after GFCI trip and power outage
- 4 Ohm typical grounded neutral
- Less than 25 ms trip response time for ground fault and grounded neutral trip
- 3 kV ringwave test and 4 kV/2 kA surge immunity test voltage surge withstand
- Operates within normal limits with 0.5 volts injected on power line 150 kHz to 230 MHz radio frequency noise susceptibility
- 3000 operations minimum endurance
- GFCI right angle cord sets are ideal for use by contractors and industrial maintenance personnel working with extension cords or portable tools
- Six times rated current overload current
- 5% maximum trip level variation effect of 10 A turn DC shock on ground fault trip
- 1500 Vrms to 1 min insulation voltage
- Mechanical indicator
- Manual reset
- Heavy impact resistant polymer material
- Provides compliance with national electric code (NEC 2008) article 590.6 for temporary installations
- Rainproof rated, UL listed for outdoor use
- To prevent unmonitored equipment startup, manual reset is required after GFCI trip and power outage
- 4 Ohm typical grounded neutral
- Less than 25 ms trip response time for ground fault and grounded neutral trip
- 3 kV ringwave test and 4 kV/2 kA surge immunity test voltage surge withstand
- Operates within normal limits with 0.5 volts injected on power line 150 kHz to 230 MHz radio frequency noise susceptibility
- 3000 operations minimum endurance
- In Stock:YesAmperage Rating:15 AColor:YellowConductor Size:12 AWGDimensions:9 in L x 2.04 in WFrequency Rating:50/60 HzMaterial:PolymerNumber of Conductors:3Operating Temperature:-35 to 66 deg CPlug Type:NEMA 5-15PReceptacle Type:NEMA 5-15RType:Type SJTW-A Heavy Duty Right AngleVoltage Rating:120 VAC