Stellar Industrial
content loaded
Klein® CL800 AC Auto-Ranging Low Impedance Mode Auto Off Digital Clamp Meter, 1000 VAC/VDC, 600 A, 60 MOhm, 50 to 400 Hz, 1-3/8 in Jaw, LCD Display

Klein® CL800 AC Auto-Ranging Low Impedance Mode Auto Off Digital Clamp Meter, 1000 VAC/VDC, 600 A, 60 MOhm, 50 to 400 Hz, 1-3/8 in Jaw, LCD Display

digital clamp meter ac/dc auto-ranging

Stellar Part #KLEIN CL800

MFG Part #CL800

MFG Name:Klein Tools

Product Description:

Klein® Digital Clamp Meter, AC Auto-Ranging Low Impedance Mode Auto Off, 1000 VAC/VDC, 600 A, 60 MOhm, 50 to 400 Hz, 1-3/8 in Jaw, Counts: 6000, LCD, +/- 2% + 5 Digits Accuracy, +/-1.5% + 5 Digits AC, +/-1.2% + 3 Digits DC Accuracy, Safety Rating: CAT IV 600 VAC, CAT III 1000 VAC, Class 2, Double Insulation, (2) AAA Batteries, 32 to 104 deg F Operating, 3.82 in W x 1.54 in D x 9.09 in H
Login For Price
  • Automatically ranging true mean squared (TRMS) technology for increased accuracy
  • AC voltage range - 6 V with accuracy of +/-(1.5% + 5 digits), 1 mV resolution, 60 V with accuracy of +/-(1.2% + 5 digits), 10 mV resolution, 600 V with accuracy of +/-(1.2% + 5 digits), 100 mV resolution, 1000 V with accuracy of +/-(1.5% + 5 digits), 1 V resolution
  • DC voltage range - 600 mV with accuracy of +/-(1% + 8 digits), 0.1 mV resolution, 6 V with accuracy of +/-(1.2% + 3 digits), 1 mV resolution, 60 V with accuracy of +/-(1.2% + 3 digits), 10 mV resolution, 600 V with accuracy of +/-(1.2% + 3 digits), 100 mV resolution, 1000 V with accuracy of +/-(1.2% + 3 digits), 1 V resolution
  • Capacitance range - 60 nF with accuracy of +/-(5% + 35 digits), 0.010 nF resolution, 600 nF with accuracy of +/-(3% + 5 digits), 0.1 nF resolution, 6 uF with accuracy of +/-(3% + 5 digits), 0.001 uF resolution, 60 uF with accuracy of +/-(3% + 5 digits), 0.01 uF resolution, 600 uF with accuracy of +/-(5% + 5 digits), 0.1 uF resolution, 6000 uF with accuracy of +/-(5% + 5 digits), 1 uF resolution
  • Dual backlit display
  • Measure AC/DC voltage, resistance, continuity, frequency and capacitance and tests diodes
  • Clamp measures AC current and thermocouple probe measure temperature
  • Low Impedance (LoZ) mode for identifying and eliminating ghost or stray voltages
  • Low battery indicator and easily accessible battery compartment
  • 2 deg pollution, 6.6 ft drop protection, 6562 ft operating altitude, IP40, 6000 uF capacitance test
  • AC current range - 60 A with accuracy of +/-(2% + 8 digits), 10 mA resolution, 600 A with accuracy of +/-(2% + 5 digits), 100 mA resolution, DC current - 60 A with accuracy of +/-(2% + 8 digits), 10 mA resolution, 600 A with accuracy of +/-(2% + 5 digits), 100 mA resolution
  • Resistance range - 600 Ohm with accuracy of +/-(1.5% + 5 digits), 0.1 Ohm resolution, 6 kOhm with accuracy of +/-(1.5% + 5 digits), 1 Ohm resolution, 60 kOhm with accuracy of +/-(1.5% + 5 digits), 10 Ohm resolution, 600 kOhm with accuracy of +/-(1.5% + 5 digits), 100 Ohm resolution, 6 MOhm with accuracy of +/-(1.5% + 5 digits), 1 kOhm resolution, 60 MOhm with accuracy of +/-(2% + 10 digits), 10 kOhm resolution